[1]
Kashou AH, Braiteh N, Kashou HE. Reversible atrioventricular block and the importance of close follow-up: Two cases of Lyme carditis. Journal of cardiology cases. 2018 May:17(5):171-174. doi: 10.1016/j.jccase.2018.01.001. Epub 2018 Feb 13
[PubMed PMID: 30279884]
Level 3 (low-level) evidence
[3]
Halbfass P, Sonne K, Nentwich K, Ene E, Deneke T. Current developments in cardiac rhythm management devices. Clinical research in cardiology : official journal of the German Cardiac Society. 2018 Aug:107(Suppl 2):100-104. doi: 10.1007/s00392-018-1313-4. Epub 2018 Jun 27
[PubMed PMID: 29951805]
[4]
Feldman MD, Zoll PM, Aroesty JM, Gervino EV, Pasternak RC, McKay RG. Hemodynamic responses to noninvasive external cardiac pacing. The American journal of medicine. 1988 Mar:84(3 Pt 1):395-400
[PubMed PMID: 3348243]
[5]
Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA 3rd, Freedman RA, Gettes LS, Gillinov AM, Gregoratos G, Hammill SC, Hayes DL, Hlatky MA, Newby LK, Page RL, Schoenfeld MH, Silka MJ, Stevenson LW, Sweeney MO, Smith SC Jr, Jacobs AK, Adams CD, Anderson JL, Buller CE, Creager MA, Ettinger SM, Faxon DP, Halperin JL, Hiratzka LF, Hunt SA, Krumholz HM, Kushner FG, Lytle BW, Nishimura RA, Ornato JP, Page RL, Riegel B, Tarkington LG, Yancy CW, American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices), American Association for Thoracic Surgery, Society of Thoracic Surgeons. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. Circulation. 2008 May 27:117(21):e350-408. doi: 10.1161/CIRCUALTIONAHA.108.189742. Epub 2008 May 15
[PubMed PMID: 18483207]
Level 1 (high-level) evidence
[6]
Murdock DK, Moran JF, Speranza D, Loeb HS, Scanlon PJ. Augmentation of cardiac output by external cardiac pacing: pacemaker-induced CPR. Pacing and clinical electrophysiology : PACE. 1986 Jan:9(1 Pt 1):127-9
[PubMed PMID: 2419842]
[7]
Ho JD, Heegaard WG, Brunette DD. Successful transcutaneous pacing in 2 severely hypothermic patients. Annals of emergency medicine. 2007 May:49(5):678-81
[PubMed PMID: 17141142]
[9]
Leong D, Sovari AA, Ehdaie A, Chakravarty T, Liu Q, Jilaihawi H, Makkar R, Wang X, Cingolani E, Shehata M. Permanent-temporary pacemakers in the management of patients with conduction abnormalities after transcatheter aortic valve replacement. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2018 Jun:52(1):111-116. doi: 10.1007/s10840-018-0345-z. Epub 2018 Mar 12
[PubMed PMID: 29532275]
[10]
Mulpuru SK, Madhavan M, McLeod CJ, Cha YM, Friedman PA. Cardiac Pacemakers: Function, Troubleshooting, and Management: Part 1 of a 2-Part Series. Journal of the American College of Cardiology. 2017 Jan 17:69(2):189-210. doi: 10.1016/j.jacc.2016.10.061. Epub
[PubMed PMID: 28081829]
[11]
Zoll PM, Zoll RH, Falk RH, Clinton JE, Eitel DR, Antman EM. External noninvasive temporary cardiac pacing: clinical trials. Circulation. 1985 May:71(5):937-44
[PubMed PMID: 3886190]
[12]
Thomas SP, Thakkar J, Kovoor P, Thiagalingam A, Ross DL. Sedation for electrophysiological procedures. Pacing and clinical electrophysiology : PACE. 2014 Jun:37(6):781-90. doi: 10.1111/pace.12370. Epub 2014 Feb 20
[PubMed PMID: 24697803]
[13]
Singleton MJ, Schoenfeld MH, Bhave PD, Beaty EH, Whalen SP. Third-degree burns caused by transcutaneous pacing for third-degree heart block. HeartRhythm case reports. 2020 Aug:6(8):495-498. doi: 10.1016/j.hrcr.2020.05.006. Epub 2020 May 18
[PubMed PMID: 32817826]
[14]
Walund DC, Lynn AM, Hall DG. A third-degree burn associated with external cardiac pacing in a five-year-old boy. The Journal of thoracic and cardiovascular surgery. 1992 Dec:104(6):1754-5
[PubMed PMID: 1453745]
[15]
Filipovic K, Bellmann B, Lüker J, Steven D, Sultan A. External electrical cardioversion of persistent atrial fibrillation in a patient with a Micra™ Transcatheter Pacing System. Indian pacing and electrophysiology journal. 2018 Jan-Feb:18(1):44-46. doi: 10.1016/j.ipej.2017.12.002. Epub 2017 Dec 18
[PubMed PMID: 29269168]
[16]
Kawata H, Pretorius V, Phan H, Mulpuru S, Gadiyaram V, Patel J, Steltzner D, Krummen D, Feld G, Birgersdotter-Green U. Utility and safety of temporary pacing using active fixation leads and externalized re-usable permanent pacemakers after lead extraction. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2013 Sep:15(9):1287-91. doi: 10.1093/europace/eut045. Epub 2013 Mar 12
[PubMed PMID: 23482613]
[17]
Sahinoglu E, Wool TJ, Wool KJ. Failure of communication and capture: The perils of temporary unipolar pacing system. Journal of arrhythmia. 2015 Jun:31(3):167-9. doi: 10.1016/j.joa.2014.09.004. Epub 2014 Oct 30
[PubMed PMID: 26336552]
[18]
Arilla Iturri S, Artázcoz Artázcoz MA. [External temporary pacemakers]. Revista de enfermeria (Barcelona, Spain). 2008 Nov:31(11):54-7
[PubMed PMID: 19203121]
[19]
Ortiz Díaz-Miguel R, Gómez Grande ML. Temporary internal pacing. Medicina intensiva. 2014 Dec:38(9):575-9. doi: 10.1016/j.medin.2014.02.006. Epub 2014 Apr 29
[PubMed PMID: 24786750]