Intraocular Pressure


Definition/Introduction

Intraocular pressure (IOP) or eye pressure is the fluid pressure of the eye. The continual production and outflow of fluids maintain this pressure. Considering that the orbital globe can be seen as a spherical rigid container, the pressure generated inside the eye is determined by external pressure and changes in the volume of the contents within. With regard to volumes, the forces generated in a normal eye are determined mainly by the dynamics of the aqueous humor (AH). Although the vitreous body (the clear gelatinous mass between the retina and the lens) fills a large portion of the posterior part of the eye, this transparent gel tends to have a fixed volume and, therefore, is not typically involved in regulating IOP.[1]

Importance of AH

The AH serves a fundamental role in the eye. The globe's shape must remain constant, and the optical channel from the cornea to the retina must remain unobstructed and relatively transparent for normal visual function. A clear substance like the AH is needed to provide volume, shape, and nutrition to all parts of the internal structures of the eye, with a minimal amount of blood vessels. Moreover, the AH helps to protect and maintain the refractive surfaces in proper positions to permit correct visual function.

Production of AH

In approaching IOP, a basic understanding of the production and outflow of the AH is helpful. This clear fluid is produced by the ciliary epithelium of the iris, ciliary body, and pars plana within the posterior chamber of the anterior eye. Plasma filtrates through the capillary walls of the ciliary process, which contributes to the chemical contribution and generation of the AH by diffusion (5%), ultrafiltration (15%), and active secretion (80%).[2]

The main secretion mechanism creates an adenosine triphosphate (ATP)-driven osmotic gradient that generates the AH in the posterior chamber, which is independent of IOP. However, the ultrafiltration AH production mechanism is influenced by plasma oncotic pressure, blood pressure in the capillaries, and IOP.

The ciliary process contains 2 apical epithelial layers surrounding a capillary and interstitial tissue-filled core.[3] The deepest layer comprises nonpigmented ciliary epithelial cells joined by tight junctions and desmosomes. Pigmented ciliary epithelial cells are found in the outer layer and are joined by gap junctions. The ciliary processes use both active secretion and ultrafiltration to produce aqueous humor.[4] Through capillary fenestrations, plasma filtrate penetrates the interstitial space (ultrafiltration). About 4% of plasma flow is filtered by the filtrate of the capillaries.[5]

The capillary wall is an essential barrier to plasma proteins; however, the tight junctions covering the apical portion of the intercellular gaps in the nonpigmented ciliary epithelium are the most important barrier. This design results from a high protein content in the tissue fluid. As a result, there is a decrease in the transcapillary difference in oncotic pressure and high oncotic pressure in the tissue fluid. Water tends to be moved into the processes from the posterior chamber by the action of hydrostatic and oncotic pressure differences across the ciliary epithelium.[6] Therefore, secretion is necessary for fluid to pass into the posterior chamber under normal circumstances.

Only active transport across the ciliary epithelial layers can deposit fluid into this chamber. The rate of AH production is about 2.5 µl/min, giving rise to about 3.5 ml in 24 hours, which undergoes daily fluctuations and tends to be higher at about noon and lowest during sleeping hours.[7] 

Outflow of AH

The AH accumulates in the posterior chamber and flows through the pupil into the anterior chamber; it then exits the anterior chamber via one of three routes:[8]

  1. The vast majority of the AH drains through the trabecular meshwork (TM) at the angle of the anterior chamber and into the Schlemm canal, where it enters episcleral veins. This outflow type is pressure-dependent and is influenced by the hydrostatic pressure in Schlemm's canal and IOP. The AH may encounter various degrees of resistance through the different layers of the TM and across the inner wall of Schlemm's canal.[9]
  2. About 20% of the AH passes from the chamber angle into the suprachoroidal space and ciliary muscle and through the scleral substance and enters uveal venous circulation in the ciliary body, choroid, and sclera. This outflow is pressure-independent. Certain glaucomatous topical drugs, like prostaglandin analogs, act on the increasing outflow from the uveoscleral pathway to decrease IOP.[10]
  3. A smaller amount of the AH transits through the iris and back into the posterior chamber. Studies have also hypothesized the existence of alternative and untraditional outflow methods, like the uveolymphatic pathway.[8]

Physiology of IOP

As pressure is a measure of force per area, IOP is a measurement involving the magnitude of the force exerted by the AH on the internal surface area of the anterior eye. The IOP can be theoretically determined by the Goldmann equation, which is IOP = (F/C) + P, where IOP is given in millimeters of mercury (mmHg), F represents the AH flow rate, C represents the AH outflow, and P is the episcleral venous pressure. A change or fluctuation in these variables will inevitably alter the IOP.[11]

IOP is carefully regulated, and disturbances are often implicated in the development of pathologies such as glaucoma, uveitis, and retinal detachment. IOP exists as a fine-tuned equilibrium between the production and drainage of the AH. Sudden increases in IOP can cause mechanical stress and ischemic effects on the retinal nerve fiber layer,[12] whereas sudden decreases in IOP can cause microbubbles to form from dissolved gases in microvasculature with resultant gas emboli and ischemic tissue damage.[13] Chronic elevation of IOP has been infamously implicated in the pathogenesis of primary open-angle glaucoma (POAG) and other vision-damaging problems.[14] 

An intricate and elegant homeostatic mechanism maintains intraocular pressure. Acutely, the sympathetic nervous system directly influences the secretion of aqueous, with beta-2 receptors causing increased secretion and alpha-2 receptors causing decreased secretion. Homeostatic regulation of IOP, however, relies primarily on regulating aqueous outflow through the TM. This regulation occurs through modulation of the resistance of the TM outflow tract in the juxtacanalicular region (region bordering Schlemm canal), likely at the level of the inner wall basement membrane.[15] IOP forces produce mechanical stress on the cells of this layer, which initiates a signal cascade leading to increased activity of matrix metalloproteinases (specifically MMP14 and MMP2) with a resultant increase in cell turnover at the level of the TM, allowing increased AH outflow.[16]

Tonometry

IOP can be measured by tonometry.[17] Numerous tonometers are currently available; however, Goldmann applanation tonometry (GAT) remains the gold standard in routine clinical settings.[18] This method, first described by Hans Goldmann in 1948, gives an accurate estimate of the pressure inside the anterior eye based on the resistance to flattening of a small area of the cornea.[19] Pressures between 11 and 21 mm Hg are considered normal, and diurnal variance of IOP is expected, with higher pressures typically found in the morning.

Although the mainline modality for measurement of IOP remains GAT, rebound tonometry using portable tonometers[20] and other alternative tonometers have been proposed in screening settings and in cases in which GAT is difficult, not appropriate, or not possible (eg, children, noncollaborative patients, postoperative eyes).[21] Readings taken with different tonometers, however, are not exchangeable.[22]

Studies have reported the development of microelectromechanical and nanoelectromechanical systems for 24-hour intraocular pressure monitoring; however, this approach currently tends only to be considered in clinical trials and research settings.[23] Although larger studies are required to validate their safety and efficacy, these newer systems will play a significant role in managing and monitoring patients with pressure-related pathology.[24]

Limitations exist in applanation technology due to reliance on the Imbert-Fick principle, which presumes that pressure within a sphere equals the force necessary to flatten its surface divided by the area flattened.[25] This principle does not consider the inherent rigidity or biomechanical properties of the corneal wall. The law applies to perfectly spherical solids that are flexible, dry, and infinitely thin, which do not reflect the anatomy of the eye.[26] The force of capillary attraction of the tear meniscus opposes corneal rigidity when the flattened area is 3.06 mm in diameter.

GAT was initially designed to calibrate a mean central cornea of 520 µm.[27] If, for example, the corneal wall is exceptionally thick in an eye with a pachymetry measurement of greater than 600 µm, a large force will be required to flatten it. The total force may not correspond to an elevated IOP, resulting in overestimating IOP. The opposite is true for individuals with thin central corneas or eyes that have undergone refractive surgery, in which the reduced mean corneal thickness can give rise to an underestimation of IOP measurements taken with GAT. For this reason, the measurement of central corneal thickness is critical for accurately measuring IOP.[28]

Normal IOP

The range of IOP that is typically considered "normal" in a clinical setting is from 10 to 21 mm Hg.[29] This normal range of IOP is based on a statistical probability of normal individuals calculated from large population-based studies performed more than 50 years ago by Leydhecker in 1958[30] and Hollows and Graham in 1966.[31] The average IOP in these large cohorts with no ocular signs or symptoms was reported to be 15-16 mmHg, with a standard deviation (SD) of 2 to 3 mm Hg. Based on a statistically normal distribution, 95% of these apparently normal individuals fall within the mean IOP +/- 2SD, giving rise to this normal range of IOP of 10 to 21 mm Hg.[32]

Ocular Hypertension and Glaucoma

Ocular hypertension (OHT) is typically defined as IOP greater than the statistical norm of 21 mmHg in eyes with open angles on gonioscopy and without detectable optic nerve head or visual field damage.[33] OHT is a primary risk factor for developing glaucoma; however, not all eyes with IOP greater than 21 mmHg will necessarily develop glaucoma. Glaucoma can be described as a pathologic condition that causes an acquired dysfunction and loss of retinal ganglion cells and axons of the optic nerve, also known as glaucomatous optic neuropathy. This neuropathy leads to a distinctive optic nerve head appearance, thinning of the retinal nerve fiber layer, and gradual loss of peripheral vision.[12]

The Ocular Hypertension Treatment Study (OHTS) showed that less than 10% of patients with OHT who did not receive medical therapy and about 5% of individuals who received local therapy developed glaucoma during the 60-month follow-up period. Yet, most did not show signs of functional or morphological glaucomatous damage.[34] It is important to note that although glaucoma is most frequently observed when IOP is above apparently normal limits, this pathology can also arise in individuals with IOP less than 21 mmHg. Normal-tension glaucoma (NTG) is defined when individuals falling within the statistically normal range of IOP show progressive glaucomatous optic neuropathy and visual field loss.[35]

Ocular Hypotony

Ocular hypotony, on the other hand, is relatively uncommon yet can be a vision-threatening condition. Hypotony tends to be defined when IOP is less than 7 mm Hg, based on similar statistical considerations of normal mean IOP minus 3SD. Hypotony is also considered for postoperative, traumatic, iatrogenic, infective, inflammatory, and pathologic conditions in which nonphysiological IOP gives rise to clinical complications that can potentially compromise vision.[36]

Variations of IOP

Similar to most biological parameters, IOP can show fluctuations and changes. IOP has a circadian rhythm, in which levels tend to be higher in the morning and less in the evening.[37] The normal range of variation in IOP in healthy individuals has been reported to be within 6 mm Hg, whereas variations beyond 10 mm Hg are considered pathological.[38] Several factors reported in the literature can influence or cause variations in IOP, including the type of tonometer, genetics, age, race, season, posture, lifestyle, exercise, refractive error, obesity, systemic diseases, medication, etc.[32]

Issues of Concern

Homeostasis of IOP is of vital importance to overall eye health and function. Disruption of this delicate balance that leads to high or low IOP may have devastating consequences, contributing to the pathogenesis of glaucoma, uveitis, and choroidal detachment.

Individuals with IOP greater than 21 mm Hg tend to be asymptomatic, considering that there is no acute central vision loss, pain, or redness if the IOP rise is not acute and severe, which can, however, be seen in cases of acute angle-closure glaucoma.[39] OHT and glaucoma are usually diagnosed during routine ophthalmologic examinations. Proper management in these patients is needed to provide early diagnosis, pertinent periodic testing, treatment, and adequate follow-up controls to limit disease progression. Although patients with OHT have normal visual fields and no detectable glaucomatous damage,[40] there is an increased incidence of POAG development.[41]

POAG is a chronic degeneration of the optic nerve characterized by the American Academy of Ophthalmology (AAO), showing evidence of optic nerve damage from optic disc abnormalities, retinal nerve fiber structure abnormalities, and reproducible visual field defects without other explanations.[42] Although the pathogenic relationship between IOP and glaucomatous optic neuropathy is not fully understood, elevated IOP is highly associated with the development of retinal ganglion cell death.

Multiple mechanisms are postulated to be the causative link between elevated IOP and the development of glaucoma. The suspicion is that elevated IOP causes direct mechanical damage to the retinal ganglion cell axons.[43] Alternatively, there have been suggestions that the elevated IOP produces a shearing of the dorsal attachments of the astrocytes from the optic nerve head, resulting in a loss of metabolic support to the optic nerve head.[44] Other possible mechanisms include ischemic damage due to compression of blood vessels supplying the optic nerve head.[45]

Recently, IOP variance has been noted to occur during the natural sleep cycle. These sleep-related fluctuations may also play a role in the progression of glaucoma, but more extensive studies are required to uncover its exact role in the pathogenesis of retinal ganglion cell death.[46] Current treatment strategies that are routinely used to manage glaucoma be it local drop therapy, laser, or surgery, are all based on lowering IOP.[47]

Anterior uveitis, an inflammation of the anterior uveal tract, frequently leads to derangement of intraocular pressure homeostasis. In some cases, inflammation of the pars plicata of the ciliary body can cause the ciliary body to shut down, resulting in IOP that is below the normal range and hypotony. In other cases, inflammation of the anterior uveal tract disrupts aqueous outflow, resulting in elevated IOP. In this case, prolonged elevation in IOP will result in glaucomatous optic neuropathy (inflammatory glaucoma).[48]

Serous choroidal detachment is a distinct danger in the setting of decreased intraocular pressure or hypotony. Increased transmural pressure secondary to decreased IOP results in the transudation of serum into the suprachoroidal space. The result is a progressive detachment of the retina and choroid.[49]

Clinical Significance

Elevated intraocular pressure is the crucial modifiable risk factor in the development of primary open-angle glaucoma. Other risk factors for glaucoma include older age, central corneal thickness, cup/disc ratio, and pattern standard deviation. In the clinical setting, a critical relevance of intraocular pressure is its utility for diagnosing and treating ocular hypertension before the development of glaucoma. The landmark Ocular Hypertension Treatment Study showed that elevated IOP in the setting of decreased corneal thickness carries a significant risk for the development of glaucoma. It has also been shown that treatment of ocular hypertension in this setting with topical ocular hypotensive medication is effective for delaying or preventing the development of primary open-angle glaucoma.[34]

Despite the proven vision-preserving benefits of early treatment, there remains a dearth of evidence for the benefits of screening for primary open-angle glaucoma in the general population. Even the cutoff of 21 mmHg for reference range IOP has been in dispute in recent years. Many patients with elevated IOP and other associated risk factors never develop visual problems. Recent AAO guidelines illustrate that the results of multiple population-based studies indicate highly variable proportions of patients with elevated IOP who develop glaucoma, suggesting poor predictive value in utilizing a specific IOP cutoff as a measure for screening and diagnosis of primary open-angle glaucoma.[42] Furthermore, the United States Preventive Service Task Force has identified significant harm in the potential overdiagnosis and overtreatment of these patients.[50] The AAO recommends comprehensive adult medical eye evaluation screening for glaucoma in all patients older than 40.[51]

Nursing, Allied Health, and Interprofessional Team Interventions

IOP is an important factor that should be assessed at every ophthalmological examination. Optometrists and ophthalmologists normally use GAT. Other tonometers can be considered in certain cases, some of which can be used by ophthalmic technicians, nurses, or emergency medicine physicians. Communication among these specialists, who work as an interprofessional team, is critical so that ocular pressure data may be appropriately compared across time.

To maintain uniformity of findings, IOP measurements may need to be remeasured across specialists over time in the management of patients. If the accuracy of a reading or device is in doubt, an alternate tonometry approach may be utilized to corroborate or dispute the reading. If IOP is not extremely high, symptoms are normally not present.

An emergent intraocular pressure reading must be obtained when acute-angle closure glaucoma is suspected based on essential and severe signs and symptoms. A physician or nurse in the emergency room should consult with an ophthalmologist to verify the pressure on arrival. Treatment should be given to lower IOP in addition to conducting other procedures to save eyesight.


Details

Author

Ryan Machiele

Updated:

2/27/2024 1:28:13 AM

References


[1]

Twa MD. Intraocular Pressure and Glaucoma. Optometry and vision science : official publication of the American Academy of Optometry. 2018 Feb:95(2):83-85. doi: 10.1097/OPX.0000000000001183. Epub     [PubMed PMID: 29389709]


[2]

Göbel K, Rüfer F, Erb C. [Physiology of aqueous humor formation, diurnal fluctuation of intraocular pressure and its significance for glaucoma]. Klinische Monatsblatter fur Augenheilkunde. 2011 Feb:228(2):104-8. doi: 10.1055/s-0029-1246040. Epub 2011 Feb 15     [PubMed PMID: 21328169]


[3]

Warjri GB, Senthil S. Imaging of the Ciliary Body: A Major Review. Seminars in ophthalmology. 2022 Aug:37(6):711-723. doi: 10.1080/08820538.2022.2085515. Epub 2022 Jun 11     [PubMed PMID: 35695216]


[4]

Fernández-Vigo JI, Kudsieh B, Shi H, De-Pablo-Gómez-de-Liaño L, Fernández-Vigo JÁ, García-Feijóo J. Diagnostic imaging of the ciliary body: Technologies, outcomes, and future perspectives. European journal of ophthalmology. 2022 Jan:32(1):75-88. doi: 10.1177/11206721211031409. Epub 2021 Jul 7     [PubMed PMID: 34233517]

Level 3 (low-level) evidence

[5]

McLaren JW. Measurement of aqueous humor flow. Experimental eye research. 2009 Apr:88(4):641-7. doi: 10.1016/j.exer.2008.10.018. Epub 2008 Nov 6     [PubMed PMID: 19026639]


[6]

Kiel JW, Hollingsworth M, Rao R, Chen M, Reitsamer HA. Ciliary blood flow and aqueous humor production. Progress in retinal and eye research. 2011 Jan:30(1):1-17. doi: 10.1016/j.preteyeres.2010.08.001. Epub 2010 Aug 27     [PubMed PMID: 20801226]


[7]

Grüb M, Mielke J. [Aqueous humor dynamics]. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 2004 Apr:101(4):357-65     [PubMed PMID: 15067416]


[8]

Costagliola C, dell'Omo R, Agnifili L, Bartollino S, Fea AM, Uva MG, Zeppa L, Mastropasqua L. How many aqueous humor outflow pathways are there? Survey of ophthalmology. 2020 Mar-Apr:65(2):144-170. doi: 10.1016/j.survophthal.2019.10.002. Epub 2019 Oct 14     [PubMed PMID: 31622628]

Level 3 (low-level) evidence

[9]

Buffault J, Labbé A, Hamard P, Brignole-Baudouin F, Baudouin C. The trabecular meshwork: Structure, function and clinical implications. A review of the literature. Journal francais d'ophtalmologie. 2020 Sep:43(7):e217-e230. doi: 10.1016/j.jfo.2020.05.002. Epub 2020 Jun 16     [PubMed PMID: 32561029]


[10]

Mehran NA, Sinha S, Razeghinejad R. New glaucoma medications: latanoprostene bunod, netarsudil, and fixed combination netarsudil-latanoprost. Eye (London, England). 2020 Jan:34(1):72-88. doi: 10.1038/s41433-019-0671-0. Epub 2019 Nov 6     [PubMed PMID: 31695162]


[11]

Casson RJ. Medical therapy for glaucoma: A review. Clinical & experimental ophthalmology. 2022 Mar:50(2):198-212. doi: 10.1111/ceo.13989. Epub 2022 Jan 17     [PubMed PMID: 35037367]


[12]

Dietze J, Blair K, Havens SJ. Glaucoma. StatPearls. 2024 Jan:():     [PubMed PMID: 30855805]


[13]

Pardianto G. Recent awareness and consideration of intraocular pressure fluctuation during eye surgery. Journal of cataract and refractive surgery. 2015 Mar:41(3):695. doi: 10.1016/j.jcrs.2015.01.009. Epub     [PubMed PMID: 25804599]


[14]

Mahabadi N, Foris LA, Tripathy K. Open Angle Glaucoma. StatPearls. 2024 Jan:():     [PubMed PMID: 28722917]


[15]

Vranka JA, Kelley MJ, Acott TS, Keller KE. Extracellular matrix in the trabecular meshwork: intraocular pressure regulation and dysregulation in glaucoma. Experimental eye research. 2015 Apr:133():112-25. doi: 10.1016/j.exer.2014.07.014. Epub     [PubMed PMID: 25819459]


[16]

Acott TS, Kelley MJ, Keller KE, Vranka JA, Abu-Hassan DW, Li X, Aga M, Bradley JM. Intraocular pressure homeostasis: maintaining balance in a high-pressure environment. Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics. 2014 Mar-Apr:30(2-3):94-101. doi: 10.1089/jop.2013.0185. Epub 2014 Jan 8     [PubMed PMID: 24401029]


[17]

Brusini P, Salvetat ML, Zeppieri M. How to Measure Intraocular Pressure: An Updated Review of Various Tonometers. Journal of clinical medicine. 2021 Aug 27:10(17):. doi: 10.3390/jcm10173860. Epub 2021 Aug 27     [PubMed PMID: 34501306]


[18]

Zeppieri M, Gurnani B. Applanation Tonometry. StatPearls. 2024 Jan:():     [PubMed PMID: 35881737]


[19]

Campbell P, Edgar DF, Shah R. Re: inter-optometrist variability of IOP measurement for modern tonometers and their agreement with Goldmann Applanation Tonometry. Clinical & experimental optometry. 2022 Apr:105(3):347-348. doi: 10.1080/08164622.2021.1987138. Epub 2022 Feb 2     [PubMed PMID: 35109782]


[20]

Brusini P, Salvetat ML, Zeppieri M, Tosoni C, Parisi L. Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients. Journal of glaucoma. 2006 Jun:15(3):213-7     [PubMed PMID: 16778643]


[21]

Bader J, Zeppieri M, Havens SJ. Tonometry. StatPearls. 2024 Jan:():     [PubMed PMID: 29630277]


[22]

Sagri D, Lösche CC, Bestges BB, Krummenauer F. [Is There Really Agreement between Rebound and Goldmann Applanation Tonometry Methods? Results of a Systematic Review of the Period 01/2005 to 08/2014]. Klinische Monatsblatter fur Augenheilkunde. 2015 Jul:232(7):850-7. doi: 10.1055/s-0035-1545995. Epub 2015 Jun 25     [PubMed PMID: 26110287]

Level 1 (high-level) evidence

[23]

Mansouri K, Weinreb RN. Ambulatory 24-h intraocular pressure monitoring in the management of glaucoma. Current opinion in ophthalmology. 2015 May:26(3):214-20. doi: 10.1097/ICU.0000000000000144. Epub     [PubMed PMID: 25784109]

Level 3 (low-level) evidence

[24]

Bhartiya S, Gangwani M, Kalra RB, Aggarwal A, Gagrani M, Sirish KN. 24-hour Intraocular pressure monitoring: the way ahead. Romanian journal of ophthalmology. 2019 Oct-Dec:63(4):315-320     [PubMed PMID: 31915728]


[25]

Mark HH. Armand Imbert, Adolf Fick, and their tonometry law. Eye (London, England). 2012 Jan:26(1):13-6. doi: 10.1038/eye.2011.248. Epub 2011 Oct 21     [PubMed PMID: 22020170]


[26]

Lu SH, Chong IT, Leung SYY, Lam DCC. Characterization of Corneal Biomechanical Properties and Determination of Natural Intraocular Pressure Using CID-GAT. Translational vision science & technology. 2019 Sep:8(5):10. doi: 10.1167/tvst.8.5.10. Epub 2019 Sep 11     [PubMed PMID: 31579556]


[27]

Erickson DH, Goodwin D, Rollins M, Belaustegui A, Anderson C. Comparison of dynamic contour tonometry and Goldmann applanation tonometry and their relationship to corneal properties, refractive error, and ocular pulse amplitude. Optometry (St. Louis, Mo.). 2009 Apr:80(4):169-74. doi: 10.1016/j.optm.2009.01.013. Epub     [PubMed PMID: 19329059]


[28]

Zeppieri M, Brusini P, Miglior S. Corneal thickness and functional damage in patients with ocular hypertension. European journal of ophthalmology. 2005 Mar-Apr:15(2):196-201     [PubMed PMID: 15812759]


[29]

Jonas JB, Aung T, Bourne RR, Bron AM, Ritch R, Panda-Jonas S. Glaucoma. Lancet (London, England). 2017 Nov 11:390(10108):2183-2193. doi: 10.1016/S0140-6736(17)31469-1. Epub 2017 May 31     [PubMed PMID: 28577860]


[30]

LEYDHECKER W, AKIYAMA K, NEUMANN HG. [Intraocular pressure in normal human eyes]. Klinische Monatsblatter fur Augenheilkunde und fur augenarztliche Fortbildung. 1958:133(5):662-70     [PubMed PMID: 13621563]


[31]

Hollows FC, Graham PA. Intra-ocular pressure, glaucoma, and glaucoma suspects in a defined population. The British journal of ophthalmology. 1966 Oct:50(10):570-86     [PubMed PMID: 5954089]


[32]

Shiose Y. Intraocular pressure: new perspectives. Survey of ophthalmology. 1990 May-Jun:34(6):413-35     [PubMed PMID: 2194306]

Level 3 (low-level) evidence

[33]

Hoffmann EM, Lamparter J. [Differentiation of ocular hypertension]. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 2016 Aug:113(8):715-28. doi: 10.1007/s00347-016-0304-y. Epub     [PubMed PMID: 27401466]


[34]

Kass MA, Heuer DK, Higginbotham EJ, Johnson CA, Keltner JL, Miller JP, Parrish RK 2nd, Wilson MR, Gordon MO. The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma. Archives of ophthalmology (Chicago, Ill. : 1960). 2002 Jun:120(6):701-13; discussion 829-30     [PubMed PMID: 12049574]

Level 1 (high-level) evidence

[35]

Esporcatte BL, Tavares IM. Normal-tension glaucoma: an update. Arquivos brasileiros de oftalmologia. 2016 Jul-Aug:79(4):270-6. doi: 10.5935/0004-2749.20160077. Epub     [PubMed PMID: 27626157]


[36]

Wang YX, Xu L, Wei WB, Jonas JB. Intraocular pressure and its normal range adjusted for ocular and systemic parameters. The Beijing Eye Study 2011. PloS one. 2018:13(5):e0196926. doi: 10.1371/journal.pone.0196926. Epub 2018 May 17     [PubMed PMID: 29771944]


[37]

Jasien JV, Turner DC, Girkin CA, Downs JC. Cyclic Pattern of Intraocular Pressure (IOP) and Transient IOP Fluctuations in Nonhuman Primates Measured with Continuous Wireless Telemetry. Current eye research. 2019 Nov:44(11):1244-1252. doi: 10.1080/02713683.2019.1629594. Epub 2019 Jun 19     [PubMed PMID: 31170817]


[38]

Singh K, Shrivastava A. Intraocular pressure fluctuations: how much do they matter? Current opinion in ophthalmology. 2009 Mar:20(2):84-7     [PubMed PMID: 19248311]

Level 3 (low-level) evidence

[39]

Khazaeni B, Zeppieri M, Khazaeni L. Acute Angle-Closure Glaucoma. StatPearls. 2024 Jan:():     [PubMed PMID: 28613607]


[40]

Boey PY, Mansberger SL. Ocular hypertension: an approach to assessment and management. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2014 Dec:49(6):489-96. doi: 10.1016/j.jcjo.2014.06.013. Epub     [PubMed PMID: 25433737]


[41]

Schuster AK, Wagner FM, Pfeiffer N, Hoffmann EM. Risk factors for open-angle glaucoma and recommendations for glaucoma screening. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 2021 Jul:118(Suppl 2):145-152. doi: 10.1007/s00347-021-01378-5. Epub 2021 Apr 21     [PubMed PMID: 33881589]


[42]

Prum BE Jr, Rosenberg LF, Gedde SJ, Mansberger SL, Stein JD, Moroi SE, Herndon LW Jr, Lim MC, Williams RD. Primary Open-Angle Glaucoma Preferred Practice Pattern(®) Guidelines. Ophthalmology. 2016 Jan:123(1):P41-P111. doi: 10.1016/j.ophtha.2015.10.053. Epub 2015 Nov 12     [PubMed PMID: 26581556]


[43]

Pang IH, Clark AF. Inducible rodent models of glaucoma. Progress in retinal and eye research. 2020 Mar:75():100799. doi: 10.1016/j.preteyeres.2019.100799. Epub 2019 Sep 23     [PubMed PMID: 31557521]


[44]

Dai C, Khaw PT, Yin ZQ, Li D, Raisman G, Li Y. Structural basis of glaucoma: the fortified astrocytes of the optic nerve head are the target of raised intraocular pressure. Glia. 2012 Jan:60(1):13-28. doi: 10.1002/glia.21242. Epub 2011 Sep 21     [PubMed PMID: 21948238]


[45]

Erichev VP,Khachatryan GK,Khomchik OV, [Current trends in studying pathogenesis of glaucoma]. Vestnik oftalmologii. 2021;     [PubMed PMID: 34669337]


[46]

McMonnies CW. The significance of intraocular pressure elevation during sleep-related postures. Clinical & experimental optometry. 2014 May:97(3):221-4. doi: 10.1111/cxo.12108. Epub 2013 Sep 11     [PubMed PMID: 24024831]


[47]

Conlon R,Saheb H,Ahmed II, Glaucoma treatment trends: a review. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2017 Feb;     [PubMed PMID: 28237137]


[48]

Martin TM, Smith JR, Rosenbaum JT. Anterior uveitis: current concepts of pathogenesis and interactions with the spondyloarthropathies. Current opinion in rheumatology. 2002 Jul:14(4):337-41     [PubMed PMID: 12118164]

Level 3 (low-level) evidence

[49]

Obuchowska I, Mariak Z. [Choroidal detachment--pathogenesis, etiology and clinical features]. Klinika oczna. 2005:107(7-9):529-32     [PubMed PMID: 16417015]


[50]

. Summaries for patients. Screening for glaucoma: U.S. Preventive Services Task Force recommendation statement. Annals of internal medicine. 2013 Oct 1:159(7):I-28     [PubMed PMID: 23836133]


[51]

Feder RS, Olsen TW, Prum BE Jr, Summers CG, Olson RJ, Williams RD, Musch DC. Comprehensive Adult Medical Eye Evaluation Preferred Practice Pattern(®) Guidelines. Ophthalmology. 2016 Jan:123(1):P209-36. doi: 10.1016/j.ophtha.2015.10.047. Epub 2015 Nov 12     [PubMed PMID: 26581558]